Skip to main content

How Much Slope Does a Shower Floor Need? 2-4% in the US, 1.25-2% in Australia

6 min read

TL;DR

  • The International Residential Code (IRC) slopes a shower floor 1/4 to 1/2 inch per foot toward the drain, about 2% to 4%.
  • Australia's housing code sets 1:80 to 1:50 (1.25% to 2%) for any wet floor with a floor drain, not only the shower.
  • The IRC prints 1/4 inch per foot as a 2 percent slope, so a floor at exactly 2% sits at the edge of both ranges.
  • At 1/4 inch per foot with a center drain, keeping one slope across the floor puts the corners of a 36-inch shower about 5/32 inch higher than the middle of each wall.

Under the International Residential Code (IRC), a shower floor falls 1/4 to 1/2 inch per foot toward the drain, about 2% to 4%. Australia's housing code asks for 1:80 to 1:50, or 1.25% to 2%. The US minimum and the Australian maximum meet near 2%. The easiest path is to pick the code where the house is and build inside its range.

Floor slope by code

Both codes give a minimum and a maximum fall, the height a floor drops per foot (or per meter) toward the drain. They cover different floors. The US numbers are for the shower floor only. The Australian numbers cover any wet floor that has a floor waste (a floor drain).

CodeMinimumMaximumFloor
US (IRC P2709.1)1/4″ per foot (about 2%)1/2″ per foot (about 4%)shower floor
Australia (NCC 10.2.12)1:80 (1.25%)1:50 (2%)wet floor with a floor waste

The IRC prints 1/4 and 1/2 inch per foot as 2 and 4 percent. On paper they are 2.08% and 4.17%, so a floor built at exactly 1/4 inch per foot is a hair steeper than Australia's 1:50 maximum, about 1/32 inch over 3 feet. Read as the code prints it, a floor at exactly 2% sits at the edge of both ranges.

How much higher the far edge must be

To turn a slope into a height, multiply the level distance from the drain to the far edge by the slope.

Distance to the drain1:801/4″ per foot1/2″ per foot
2 ft0.3″1/2″1″
3 ft0.45″3/4″1½″
4 ft0.6″1″2″
5 ft0.75″1¼″2½″

With a linear drain along one wall, the whole floor slopes one way. Use the distance to the opposite wall.

With a center drain, check the corners separately. In a 36-by-36-inch shower, a corner is about 25½ inches from the drain, so at 1/4 inch per foot it must sit just over 1/2 inch above the drain. The middle of each wall is 18 inches away and sits 3/8 inch higher. To keep one slope across the floor, each corner has to be about 5/32 inch higher than the middle of the walls next to it.

What Korea's standard specifications say

The two Korean standard specifications I checked have no shower-only clause, and they give different numbers for a floor slope. The membrane is the waterproof layer laid below the tile, and the mortar bed is the layer of cement mortar that the floor tile is set on.

In the waterproofing specification (KCS 41 40 01), clause 3.1.3 (1) covers roof slabs and indoor floors whose membrane is protected by cast concrete or similar. It sets the base under that membrane at 1/100 to 1/50 (1% to 2%). In the tile specification (KCS 41 48 01), clause 3.1 (11) covers the mortar bed. It says the floor keeps a slope so that water does not pool, but by no more than 1/100 (1%).

The tile specification also puts the slope and the drain details into the tile layout drawing made before the work. If you are having a bathroom redone in Korea, check that drawing for the slope number.

Reading a shower floor's fall with a phone

A tiled floor is uneven, so a phone laid right on it reads the tilt of one tile. Lay a straight board or a long level from the far edge to the drain, and measure on top of it.

The pipe mode of PitchFall, a slope level app for phones, shows fall in inches per foot, percent or 1:n, the same units the floor codes use.

  1. Lay the board from the far wall to the drain. With a center drain, also lay it from a corner.
  2. In pipe mode, type a custom target near the middle of your range: 3/8″ per foot under the IRC, or 1:65 in Australia (switch the unit to 1:n). "On target" covers a band around the target, ±1/32″ per foot or ±0.2% by default, so a target at the edge of the range lets that band spill outside it.
  3. Stand the phone on its long edge on the board and read the status line. On target means near your target; otherwise it says too flat or too steep.
  4. Too flat means the drain end is not low enough yet. Too steep means the far edge is too high or the drain end too low, which matters most under Australia's 1:50 maximum. Compare the big number on the screen with your range, then reset the floor height before the tile goes down.

The same check works on the ground around a house and on a drain pipe.

FAQ

Does the waterproof liner need slope too?

Yes, under the IRC. Section P2709.3 says the shower liner must slope 1/4 inch per foot (about 2%) to the weep holes in the subdrain. Korea's waterproofing specification sets 1/100 to 1/50 for the base under a membrane that a covering layer protects (1/50 to 1/20 when the membrane has only a top coat or no finish).

Sources

A slope level that tells you how much to move it