What Is the Minimum Roof Pitch? Asphalt Shingles, Tile, Metal and Slate

4 min read

TL;DR

  • Under the 2024 International Residential Code, asphalt shingles need at least 2/12, clay or concrete tile 2½/12, wood shingles and shakes 3/12, and slate 4/12.
  • From the minimum up to 4/12, asphalt shingles and tile need two layers of underlayment instead of one.
  • Metal panels depend on the seams: 3/12 for lapped seams with no sealant, 1/2 in 12 with sealant, and 1/4 in 12 for standing seam.

Under the US residential code, asphalt shingles need a roof pitch of at least 2/12, clay or concrete tile 2½/12, wood shingles 3/12 and slate 4/12. Some metal panel roofs can go much lower, and how low depends on the seams.

Minimum pitch by roofing material

The 2024 International Residential Code (IRC) sets a minimum slope in the section for each roof covering. A pitch of 2/12 means the roof rises 2 inches for every 12 inches it runs horizontally. The IRC is a model code: your state, city or county adopts an edition, sometimes with local changes, so your local building department has the final word.

RoofingMinimum pitchPercentDegreesIRC section
Asphalt shingles2/1216.7%9.5°R905.2.2
Clay or concrete tile2½/1220.8%11.8°R905.3.2
Metal shingles3/1225%14.0°R905.4.2
Wood shingles and shakes3/1225%14.0°R905.7.2, R905.8.2
Slate4/1233.3%18.4°R905.6.2
Mineral-surfaced roll roofing1/128.3%4.8°R905.5.2
Built-up (not coal-tar), modified bitumen, single-ply membrane1/4 in 122.1%1.2°R905.9.1, R905.11.1, R905.12.1

The percent and degree columns are our conversions of each pitch. The code also prints a percent in parentheses. For tile it prints 25% next to 2½/12, but 2½ in 12 works out to 20.8%, so the table goes by the ratio.

Is a 2/12 roof pitch OK?

At 2/12, asphalt shingles are allowed with two layers of underlayment. Roll roofing, sealed lapped metal panels and standing-seam metal are allowed too. Tile, metal shingles, wood shingles and shakes, slate and lapped metal panels without sealant need a steeper roof.

Underlayment is the sheet under the shingles. For asphalt shingles on a slope from 2/12 up to 4/12, the code asks for two layers of underlayment instead of one. Clay and concrete tile need the double layer too, from 2½/12 to 4/12. So a 3/12 shingle roof is allowed, but it takes more underlayment than a 5/12 roof.

Metal roofs depend on the seams

Under the code, lapped metal panels with no sealant need 3/12. Lapped panels with sealant in the laps can go down to 1/2 in 12, about 4%. Standing-seam roofs can go down to 1/4 in 12, about 2%. For a metal roof, find out the seam type before you look up the pitch.

Measuring from the attic

A common rafter runs in the direction of the roof slope, so it has the same pitch as the roof above it. Hip and valley rafters run on the diagonal and read flatter, so skip them. These steps use the phone slope level PitchFall.

  1. Open PitchFall's Roof mode. It shows pitch in x/12 in the US.
  2. Hold the long edge of the phone along the side or the underside of a common rafter, and check that the number is at or above the minimum for your roofing.
  3. To have the app tell you, set the target to that minimum, for example 2/12 for asphalt shingles. When the rafter is flatter, the screen says Too flat and shows the difference. Close to the target it says On target, so read the number when the pitch sits right at the minimum. Too steep only means steeper than the target; for a minimum, steeper is fine.

If you are using PitchFall for the first time or have changed the phone's case, calibrate first: measure, turn the phone end for end on the same spot, and measure again. The app works out the phone's own error from the two readings and keeps it as its correction.